OXYGUARD STATIONARY PROBE

Principle of measurement Membrane covered polarographic oxygen probe, self polarizing galvanic cell, automatic temperature compensation
Oxygen Probe
Output signal Approximately 5mV per mg/l, 2mV per % vol/vol
Output impedance Approximately 1K ohm
Oxygen Probe Model 420      
Process signal 4-20 mA
Loop power supply 15-35V DC, typically 24V DC,
Allowable loop resistance Up to 1000 ohms.
Stationary Oxygen Probes Type I Type II Type III
Range: Dissolved Oxygen 0-40mg/l, 0-400% Sat 0-15 mg/l, 0-150% 0-40mg/1,
0-400% Sat
Range: Gaseous Oxygen 0-100% Vol / Vol 0-35% Vol / Vol 0-100% Vol / Vol
Temperature compensation Automatic from 4° - 40°C (40° - 104°F)
Accuracy Better than ±2% of reading when calibration temperature equals measuring temperature ±5 C. Zero drift less than 1 mg/l
Repeatability: mg/l Better than ±0.2 mg/l
Repeatability: %Vol Better than ±0.5% vol/vol when barometric pressure unchanged
Response time: mg/l 1 minute for 90% of 100% step change at constant temperature
Response time: %Vol 10 secs. for 90% of 100% step change at constant temperature
Construction Materials Type I Type II Type III
Probe electrodes Silver cathode / Zinc anode Silver cathode / Lead anode Silver cathode / Type III anode
Probe electrolyte NaCl Na2CO3 Type III electrolyte
Probe body POM (poly-oxy-methylene)
O-rings Viton
Membrane 50 µm (2 mil) teflon
Dimensions & Weight
Stationary Oxygen Probe 58mm diameter x 59mm high (2 1/4in dia. x 2 1/2in)
350g (3/4lb) including standard 3m (10ft) cable length
Oxygen Probe Model 420 58 mm diameter x 88 mm high (2 1/4in dia. x 3 1/2in)
350 g (1 1/2lb) including standard 3m (10ft) cable length
Cable 2-conductor, 0.75 mm2 (16 gauge), standard length 3 m (10 ft), other lengths available upon request
Operating Conditions
Temperature 0° to 40°C (32° to 104°F)
Pressure Maximum 10 atmospheres (147 psig.)
Minimum submersion depth 60mm (2 1/2in)
Minimum water flow 2.5cm/s (1 in/sec) across membrane
Calibration In air, or air saturated water (Use of EasyCal calibrator optional).