The new Quatro cable attached to the Pro Plus allows you to utilize 4-ports to measure temperature/conductivity, DO, and any two ISEs among pH, ORP, ammonium, chloride, or nitrate creating an extremely powerful handheld multiparameter instrument.
Toughest
The Pro Plus instrument meets the demands of true field work. The instrument is rated to IP-67 standards even without the battery cover on. Other tough features include a 3-year warranty, Mil-spec connectors, rubber overmolded case, and a 2-year cable warranty. In-house testing procedures also include 1-meter drop tests from all angles to ensure expected field-durability.
Smartest
The instrument provides numerous benefits from the following features; 2,000 data-set memory, password protection, backlit display and keypad, graphic display with detailed Help functionality, re-cal prompts, user defined fields, detailed GLP, auto stable, Hold All Readings function,
Data Manager software for the desktop, USB connection, auto-buffer recognition, and flexible folders and site lists for logging data.
Most Versatile
Connect any Professional Series cable (excludes ODO cables) and probe option to the instrument and use the convenient cable management kit to keep everything simple and organized. Cable options range from 1-, 4-, 10-, 20-, and 30-meter choices (up to 100-meters on DO only cables). Use lab or field probes and switch between the two quickly. The Pro Plus makes an ideal lab BOD instrument with the proven self-stirring BOD probe. A convenient handstrap can be used on either side of the instrument. A complete family of accessories also increases the versatility of the Pro Plus. Choose among accessories including carrying cases, flow cells, cable weight, belt clip, tripod, and c-clamp.
Free - Data Manager
Data management can become a daunting task over time but with the Data Manager software this task is much simpler and efficient. Download data, configure instruments, and conduct real-time studies easily with Data Manager software. View data graphically or in tabular form and export data as needed to other programs. Data Manager software is a very powerful tool. So powerful in fact, that we give it to you at no charge when purchasing a Pro Plus. After all, it's all about the data!
When purchasing the Pro Plus you will receive the instrument, manual, batteries, communications saddle, USB cable, and Data Manager software. Cables and probes are ordered separately.
Features
- IP-67 with 3-year warranty
- 5,000 data-set memory
- Interval or single event logging
- Free - Data Manager software
- Measure a variety of parameter combinations
Professional Plus Instrument General Specifications
Auto Stable
|
User-defined auto-stable function holds stable readings on display when criteria is met |
| Barometer |
Built-in barometer |
Buffer Recognition
|
Auto buffer recognition for US and NIST buffers |
| Certifications |
RoHS, CE, WEEE, C-Tick, VCCI, FCC, IP-67, 1-meter drop test, Assembled in USA |
| Connectivity |
USB 2.0; ProComm II communications saddle and USB cable included; user-upgradeable software via USB and website |
| Connector |
MS (military spec) waterproof with bayonet lock |
| Data Management |
Data Manager desktop software included; 100 user-defined folders and site names |
| Data Memory |
5,000 data sets (data, date, time, user-defined info); 100 GLP files |
| Dimensions |
8.3 cm width x 21.6 cm length x 5.6 cm depth (3.25 in x 8.5 in x 2.21 in) |
| Display |
Graphic display with detailed Help; backlit display AND keypad |
DO Membrane Response Times
(T95; 100%-0) and Flow Dependence
|
1.25 mil PE = 8 seconds and 6 in/sec flow
2.0 mil PE = 17 seconds and 3 in/sec flow
1 mil Tefl on® = 18 seconds and 12 in/sec flow |
DO Sensors
|
Polarographic or galvanic field sensors; self-stirring polarographic BOD sensor for the lab |
Field Cables
|
Standard lengths of 1, 4, 10, 20, or 30 meters - up to 100 meters on DO only cables; all 4-meter and longer cables include a cable management kit |
Flow Cell
|
Single, dual and multiparameter Quatro cable all flow cell compatible |
| GLP Compliance |
Yes; detailed GLP information is stored and is available to view, download or print |
Lab Cables
|
BOD sensor includes 2-meter cable; 1 or 4 meters on lab pH, ORP and pH/ORP cables |
| Languages |
English, Spanish, German, French, Italian, Norwegian, Portuguese, Japanese, Chinese (Simplified & Traditional) |
| Logging Modes |
Single or Continuous |
| Operating Temperature |
-10 to 60°C |
| Power |
2 alkaline C-cells provide 80 continuous hours at ambient temperature without backlight; ProComm II saddle provides USB power or optional wall power, cigarette lighter, and universal cell phone charger options |
| Storage Temperature |
-20 to 70°C |
| User ID |
Optional user ID for data security |
Warranty
|
3-year instrument; 2-year field cables |
Waterproof
|
IP-67 (even with the battery cover off); floats |
Weight with Batteries
|
475 grams (1.05 lbs) |
Professional Plus System Specifications (Cables & Sensors)
|
Sensor Type |
Range |
Accuracy |
Resolution |
Units |
Calibration |
Dissolved Oxygen (%)
(temp comp range -5 to 45°C) |
Polarographic or Galvanic |
0 to 500% |
0 to 200%
(± 2% of reading or 2% air saturation, whichever is greater)
200% – 500% (± 6% of reading) |
1% or 0.1% air saturation
(user selectable) |
%
|
1 or 2-points with zero |
Dissolved Oxygen (mg/L)
(temp comp range -5 to 45°C) |
Polarographic or Galvanic |
0 to 50 mg/L |
0 to 20 mg/L
(± 2% of reading or 0.2 mg/L, whichever is greater)
20 – 50 mg/L (± 6% of reading) |
0.1 or 0.01 mg/L (user selectable); 0.1% air saturation
|
mg/L, ppm
|
1 or 2-points with zero |
Temperature
(Field rugged cables) |
|
-5 to 70°C |
±0.2°C |
0.1°C |
°C, °F, K |
|
Temperature
(Lab-grade)* |
|
0 to 40°C |
±0.35°C |
0.1°C |
°C, °F, K |
|
| Conductivity** |
Four electrode cell |
0 to 200 mS/cm
(auto range)
|
±0.5% of reading or 0.001 mS/cm, whichever is greater (4-m cable) ±1% of reading or 0.001 mS/cm, whichever is greater (20-m cable) |
0.001 mS/cm to 0.1 mS/cm (range dependent) |
µS, mS
|
1 point |
| Salinity |
Calculated from conductivity and temperature |
0 to 70 ppt |
±1.0% of reading or 0.1 ppt, whichever is greater |
0.01 ppt |
ppt, PSU
|
1 point
|
| pH |
Glass Combination Electrode |
0 to 14 units |
±0.2 units |
0.01 units |
mV, pH units
|
1, 2, 3, 4, 5, or 6 point (user selectable); US, NIST or Custom Buffers |
| ORP |
Platinum button |
--1999 to +1999 mV |
±20 mV in redox standards |
0.1 mV
|
mV |
1 point |
Ammonium***
(ammonia with pH sensor)
|
Ion Selective Electrode
|
0 to 200 mg/L-N, 0 to 30°C |
±10% of reading or 2 mg/L-N, whichever is greater |
0.01 mg/L |
mg/L-N, mV
|
1, 2, or 3 point
(user selectable)
|
| Nitrate*** |
Ion Selective Electrode
|
0 to 200 mg/L-N, 0 to 30°C |
±10% of reading or 2 mg/L-N, whichever is greater |
0.01 mg/L |
mg/L-N, mV
|
1, 2, or 3 point
(user selectable) |
Chloride***
|
Ion Selective Electrode
|
0 to 1000 mg/L, 0 to 40°C
|
±15% of reading or 5 mg/L, whichever is greater |
0.01 mg/L |
mg/L-Cl-, mV
|
1, 2, or 3 point
(user selectable) |
Total Dissolved Solids (TDS)
|
Calculated from conductivity and temperature
|
0 to 100 g/L TDS constant range 0.30 to 1.00 (0.64 default) |
|
0.001, 0.01, 0.1g/L |
kg/L, g/L |
|
| Barometer |
Piezoresistive |
375 to 825 mmHg |
±1.5 mmHg from 0 to 50°C |
0.1 mmHg
|
mmHg, inHg, mbar, psi, kPa, ATM |
1 point |
| Instrument Only Specifications (at Ambient Temperature) |
| pH |
|
-2.60 to 16.60
|
±0.1 mV (0.01 pH units)
|
0.1 mV (0.01 pH units) |
|
|
| ORP |
|
-1999 to +1999 mV
|
±0.5 mV
|
0.1 mV |
|
|
| Conductivity |
|
0.0 to 200 mS/cm each range
|
±0.1% FS ±1 digit for µS/cm to 0.1 mS/cm (range dependent) |
0.0001 mS/cm or 0.1 |
|
|
| Dissolved Oxygen |
|
0.00 to 90 mg/L; 0 to 550% |
±0.2% FS (550% air saturation) ±1 digit (with 1.25 PE membrane at 10°C) |
0.01 mg/L; 0.1% air saturation |
|
|
| Temperature |
|
-10 to 100.00°C |
±0.2% FS ±1 digit
|
0.1°C
|
°C, °F, K |
|
|
*Lab-grade cables include 605107, -108, -109, 605177, -178, -179
** Derived parameters can include resistivity, salinity, specifi c conductance, and total dissolved solids
***ISE sensors for freshwater only; 17-meter maximum depth
|
Ordering Guide
| Step 1: |
Order Instrument |
Item #
|
Description |
| 6050000 |
Instrument, includes Data Manager software, the ProComm II communications saddle, and USB cable |
| |
|
Step 2:
|
Order Cable(s)
All cables include temperature; cables over 1 meter include cable management kit; cables with conductivity include sensor (no need to order conductivity sensor) |
| 60510 |
1, 4, 10, 20 or 30 meter: ISE1/temp |
| 60520 |
1, 4, 10, 20, 30 or up to100 meters2: DO/temp |
| 60530 |
1, 4, 10, 20 or 30 meter: conductivity/temp |
| 6051010 |
1, 4, 10, 20 or 30 meter: ISE/ISE/temp |
| 6051020 |
1, 4, 10, 20 or 30 meter: ISE/DO/temp |
| 6051030 |
1, 4, 10, 20 or 30 meter: ISE/conductivity/temp |
| 6052030 |
1, 4, 10, 20 or 30 meter: DO/conductivity/temp |
| 605790 |
1, 4, 10, 20 or 30 meter: ISE/ISE/DO/conductivity/temp |
| 605107 |
1–meter single junction pH sensor & cable |
| 605177 |
4–meter single junction pH sensor & cable |
| 605108 |
1–meter single junction ORP sensor & cable |
| 605178 |
4–meter single junction ORP sensor & cable |
| 605109 |
1–meter single junction pH/ORP sensor & cable |
| 605179 |
4–meter single junction pH/ORP sensor & cable |
| |
|
Step 3:
|
Order Sensor(s) |
| 605202 |
Galvanic DO |
| 605203 |
Polarographic DO |
| 605780 |
Self-stirring BOD (2-meter cable included) |
| 605101 |
pH (ISE) |
| 605102 |
ORP (ISE) |
| 605103 |
pH/ORP combination (ISE)3
|
| 605104 |
Ammonium (ISE) |
| 605105 |
Chloride (ISE) |
| 605106 |
Nitrate (ISE) |
1 ISEs include pH, ORP, Ammonium, Nitrate, Chloride
2 Special order cables in 10-meter increments up to 100 meter available
3 Not recommended on 6051010 or 605790 cables. Only pH would appear. |
|
|
|